Power Spectral Density (PSD)
What is power spectral density?
Power spectral density (PSD, also called the spectral density or power density spectrum) describes how a signal's power is spread across frequency, as power per hertz of bandwidth. It is the standard way to measure noise and random vibration: peaks show frequencies that carry a lot of power, and the area under the curve is the signal's total power.

The PSD of two tones in white noise: one periodogram (orange) and the Welch average of 127 segments (blue), sample data. Try the interactive version, where you can change the segment length, overlap, window and number of averages.
- A PSD gives power per unit of frequency, in units such as V²/Hz, g²/Hz or dB/Hz.
- Dividing by the bin width makes noise read the same level whatever the FFT size, which is why it is called a density.
- The area under the PSD is the mean square of the signal (the average of its squared samples), so its square root is the RMS. In vibration testing, where the signal is acceleration in g, that RMS is called Grms.
- A single periodogram (one FFT, squared and scaled) is very noisy. Welch's method averages the periodograms of many windowed, overlapping segments to steady it, at the cost of frequency resolution.
- Use an amplitude spectrum for tones and a PSD for noise and broadband signals.
Why "density"? Power per hertz explained
An FFT splits a block of samples into frequency bins, each wide, where is the sample rate and the block length. (The FFT guide explains bins in detail.) The squared magnitude of each bin is the power that falls inside it.
That power depends on how wide the bin is:
- A steady tone puts all its power into one bin, whatever the bin width. Its power reading stays the same as changes.
- Broadband noise spreads its power across every frequency. Make the bins half as wide and each catches half as much, so the noise floor in a power spectrum falls by 3 dB each time you double .
So a plain power or amplitude spectrum of noise has no fixed level; it depends on a setting chosen by whoever ran the analysis. Dividing each bin's power by its width fixes that. The result, power per hertz, is the same for any FFT size, sample rate or instrument. Two labs can compare noise floors, and a vibration test can specify a level that any controller reproduces.
The trade goes the other way for tones. In a PSD, a tone's peak rises 3 dB for each doubling of , because the same power is divided by an ever narrower bin. A PSD peak's height therefore isn't the tone's level. To read a tone's size, use an amplitude spectrum, or add up the PSD across the peak (see Parseval's check).
The formal definition
For a stationary random signal, the PSD is the Fourier transform of its autocorrelation , the average of (the Wiener–Khinchin theorem):
In practice nobody has an infinitely long recording, so the PSD is estimated from a finite block of samples.
PSD units and dB/Hz
The unit of a PSD is the square of the signal's unit, per hertz. Plots often show it in decibels, because a PSD can span many powers of ten.
| Signal | PSD unit | In decibels | Square root (amplitude density) | Where you'll see it |
|---|---|---|---|---|
| Voltage | V²/Hz | dB re 1 V²/Hz, often written dB/Hz or dBV/Hz | V/√Hz (nV/√Hz on data sheets) | Electronics, sensors, op-amp and ADC noise |
| Acceleration | g²/Hz | dB re 1 g²/Hz | g/√Hz | Random vibration testing, accelerometer noise |
| Sound pressure | Pa²/Hz | dB re (20 µPa)²/Hz | Pa/√Hz | Acoustics, noise measurement |
| Electrical power | W/Hz or mW/Hz | dBm/Hz (dB re 1 mW/Hz) | none | Radio, communications, noise figure |
| Brain or muscle signals | µV²/Hz | dB re 1 µV²/Hz | µV/√Hz | EEG and EMG band power |
Converting a PSD to and from decibels
A PSD in dB is , using 10 rather than 20 because a PSD is already a power. So 2.44 × 10⁻⁴ V²/Hz is −36.1 dB re 1 V²/Hz, and its square root is 15.6 mV/√Hz. Every 10 dB is a factor of 10 in power density.
The density works the same way for power in watts. A radio receiver's thermal noise floor is about −174 dBm/Hz at the standard reference temperature of 290 K, close to room temperature. In a 1 MHz bandwidth (60 dB above 1 Hz), that adds up to about −114 dBm. The density lets you work out the noise in any bandwidth by adding .
How to read a PSD plot
A PSD plot (also called a PSD curve or PSD graph) has frequency along the horizontal axis and power density up the vertical axis, nearly always on a log or dB scale.
- Check the units on the vertical axis. V²/Hz, g²/Hz or dB/Hz means a density. If it's V, V² or dB with no "/Hz", it's an amplitude or power spectrum, and noise levels won't compare across settings.
- Read the noise floor. The broad level between peaks is the background noise density, which sets the signal-to-noise ratio. On a dB/Hz scale, a 3 dB step is a doubling of power density.
- Look at its slope. A flat floor is white noise. One that falls 3 dB per octave (10 dB per decade) is pink noise, or 1/f noise, common in electronics, music and nature. A 6 dB per octave fall is brown (red) noise, which looks like a random walk. Plot frequency on a log axis to see slopes as straight lines.
- Find the peaks. A narrow peak is a tone: a hum, a rotating part or a clock. A wider hump is a resonance, such as a structure's natural frequency.
- Read power in a band as the area under the curve between two frequencies, not as a height. EEG band power (for example, the alpha band around 8 to 13 Hz) and vibration Grms are found this way.
How to calculate power spectral density
The basic estimate is the periodogram: one windowed FFT, squared and scaled to a density. Welch's method averages many of them.
Step 1: the periodogram
Take samples , multiply them by a window (such as Hann), run an FFT and square the magnitude. Then scale bin so it reads as power per hertz: